Country/Region:GLOBAL | Overseas

Home > About Us > FXICC Test Laboratory > Test Items > EMC (Electromagnetic Compatibility)
Start Contents

Third Party Accredited FXICC Test Laboratory

Test Items / Test Facilities EMC (Electromagnetic Compatibility)

1. Standard Numbers (Scope)

1-1. Electromagnetic Interference (EMI)

    • IEC/EN 61000-6-3*
    • IEC/EN 61000-6-4*
    • IEC/EN 61326*
    • IEC/EN 61000-3-2
    • IEC/EN 61000-3-3
    • IEC/EN 61000-3-11
    • IEC/EN 61000-3-12
    • FCC Part 15B
    • EN 50081-1 (Replaced by EN61000-6 series)
    • EN 50082-2 (Replaced by EN61000-6 series)
    • EN 55011
    • EN 55014-1
    • EN 55022
    • CISPR Publ. 11
    • CISPR Publ. 14-1
    • CISPR Publ. 22

*Started the test service from February 7, 2008.


1-2. Immunity

    • IEC/EN 61000-6-1*
    • IEC/EN 61000-6-2*
    • IEC/EN 61000-4-34*
    • EN 55014-2
    • EN 55024
    • CISPR Publ. 14-2
    • CISPR Publ. 24
    • IEC/EN 61000-4-2
    • IEC/EN 61000-4-3
    • IEC/EN 61000-4-4
    • IEC/EN 61000-4-5
    • IEC/EN 61000-4-6
    • IEC/EN 61000-4-8
    • IEC/EN 61000-4-11

*Started the test service from February 7, 2008.


1-3. Local Standard

Although the following standards are not included within the scope of BELAC accreditation, FXICC Test Laboratory can offer the test data for applying for compliance with such standards:

  • VCCI (Japan) : VCCI-3-2063.1
  • MIC (Korea) : KN22、KN24

2. Overview of the Test Facilities

2-1. Anechoic Chamber for EMI

10-meter Anechoic Chamber (nicknamed "Neptune")

Measurement Distance : 3m, 10m
Turn Table Size : Φ3m and Φ10m in diameter
Weight Limits : Φ3m - 3,000kg; Φ10m - 10,000kg
Size of Carrying-in Entrance : 3.0 (W) × 3.0 (H) m
Test Frequency : 30MHz~18GHz
Power capacity : Single Phase / Three Phase : 90kVA
Power Outlet Frequency : 50Hz, 60Hz
10-meter Anechoic Chamber-II (nicknamed "Verze")

Anechoic chamber with the latest vertical ground reference plane

Measurement Distance : 3m, 10m
Turn Table Size : Φ5m in diameter,Weight Limit: 5,000kg
Size of Carrying-in Entrance : 3.0(W) × 3.0 (H) m
Test Frequency : 30MHz~40GHz
Power capacity : Single Phase / Three Phase : 45kVA
Size of Vertical Ground Reference Plane : 5.0 (W) × 2.0 (H) m (max.)
Power Outlet Frequency : 50Hz, 60Hz

2-2. Shield Room for Immunity

Shield Room for Immunity (nicknamed "Graz")

Shield Room Size : 6.0 (W) ×10.0 (L) ×3.0 (H) m
(Internal Usable Dimensions)
Test Standards : EN / IEC 61000-4-2
EN / IEC 61000-4-4
EN / IEC 61000-4-5
EN / IEC 61000-4-6
EN / IEC 61000-4-11
Size of Carrying-in Entrance : 2.4 (W) × 2.0 (H) m
Power capacity : Single Phase / Three Phase : 8kVA and 12kVA (2systems)
Shield Capacity : 9KHz~40GHz
Power Outlet Frequency : 50Hz, 60Hz
Other Test Standards : EN / IEC 61000-4-8 (in Ambient Chamber)
EN / IEC 61000-3-2 (in another chamber for harmonics)
EN / IEC 61000-3-3 (in another chamber for flicker)
end of content