Although the following standards are not included within the scope of BELAC accreditation, FXICC Test Laboratory can offer the test data for applying for compliance with such standards:

| Measurement Distance | : | 3m, 10m | ||
|---|---|---|---|---|
| Turn Table Size | : | Φ3m and Φ10m in diameter Weight Limits : Φ3m - 3,000kg; Φ10m - 10,000kg |
||
| Size of Carrying-in Entrance | : | 3.0 (W) × 3.0 (H) m | ||
| Test Frequency | : | 30MHz~18GHz | ||
| Power capacity | : | Single Phase : 45kVA Three Phase : 90kVA |
||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||


| Measurement Distance | : | 3m, 10m | ||
|---|---|---|---|---|
| Turn Table Size | : | Φ5m in diameter,Weight Limit: 5,000kg | ||
| Size of Carrying-in Entrance | : | 3.0(W) × 3.0 (H) m | ||
| Test Frequency | : | 30MHz~40GHz | ||
| Power capacity | : | Single Phase / Three Phase : 45kVA | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||
| Size of Vertical Ground Reference Plane | : | 5.0 (W) × 2.0 (H) m (max.) | ||


| Measurement Distance | : | 3m, 10m | ||
|---|---|---|---|---|
| Turn Table Size | : | Φ3m and Φ5m in diameter Weight Limits : Φ3m / 5m - 5,000kg |
||
| Size of Carrying-in Entrance | : | 2.5 (W) × 2.5 (H) m | ||
| Test Frequency | : | 30MHz~18GHz | ||
| Power capacity | : | Single Phase / Three Phase : 36kVA | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||
| Size of Vertical Ground Reference Plane | : | 5.0 (W) × 2.4 (H) m (max.) | ||

| Shield Room Size | : | 6.0 (W) ×10.0 (L) ×3.0 (H) m (Internal Usable Dimensions) |
||
|---|---|---|---|---|
| Size of Carrying-in Entrance | : | 2.4 (W) × 2.0 (H) m | ||
| Shield Capacity | : | 9KHz~40GHz | ||
| Power capacity | : | Single Phase / Three Phase : 8kVA and 12kVA (2systems) | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||
| Shield Room Size | : | 6.0 (W) ×8.0 (L) ×3.0 (H) m (Internal Usable Dimensions) |
||
|---|---|---|---|---|
| Size of Carrying-in Entrance | : | 2.0 (W) × 2.0 (H) m | ||
| Shield Capacity | : | 9KHz~40GHz | ||
| Power capacity | : | Single Phase / Three Phase : 8kVA and 12kVA (2systems) | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||

| Shield Room Size | : | 5.0 (W) ×8.0 (L) ×2.5 (H) m (Internal Usable Dimensions) |
||
|---|---|---|---|---|
| Size of Carrying-in Entrance | : | 2.0 (W) × 2.1 (H) m | ||
| Shield Capacity | : | 9KHz~40GHz | ||
| Power capacity | : | Single Phase / Three Phase : 6kVA and 8kVA (2systems) | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||