1-1. Electromagnetic Interference (EMI)
-
- IEC/EN 61000-6-3*
- IEC/EN 61000-6-4*
- IEC/EN 61326*
- IEC/EN 61000-3-2
- IEC/EN 61000-3-3
- IEC/EN 61000-3-11
- IEC/EN 61000-3-12
- FCC Part 15B
-
EN 50081-1(Replaced by EN61000-6 series)EN 50082-2(Replaced by EN61000-6 series)- EN 55011
- EN 55014-1
- EN 55022
- CISPR Publ. 11
- CISPR Publ. 14-1
- CISPR Publ. 22
*Started the test service from February 7, 2008.
1-2. Immunity
-
- IEC/EN 61000-6-1*
- IEC/EN 61000-6-2*
- IEC/EN 61000-4-34*
- EN 55014-2
- EN 55024
- CISPR Publ. 14-2
- CISPR Publ. 24
-
- IEC/EN 61000-4-2
- IEC/EN 61000-4-3
- IEC/EN 61000-4-4
- IEC/EN 61000-4-5
- IEC/EN 61000-4-6
- IEC/EN 61000-4-8
- IEC/EN 61000-4-11
*Started the test service from February 7, 2008.
1-3. Local Standard
Although the following standards are not included within the scope of BELAC accreditation, FXICC Test Laboratory can offer the test data for applying for compliance with such standards:
- VCCI (Japan) : VCCI-3-2063.1
- MIC (Korea) : KN22、KN24
2-1. Anechoic Chamber for EMI
10-meter Anechoic Chamber (nicknamed "Neptune")

| Measurement Distance | : | 3m, 10m | ||
|---|---|---|---|---|
| Turn Table Size | : | Φ3m and Φ10m in diameter Weight Limits : Φ3m - 3,000kg; Φ10m - 10,000kg |
||
| Size of Carrying-in Entrance | : | 3.0 (W) × 3.0 (H) m | ||
| Test Frequency | : | 30MHz~18GHz | ||
| Power capacity | : | Single Phase / Three Phase : 90kVA | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||
10-meter Anechoic Chamber-II (nicknamed "Verze")


| Measurement Distance | : | 3m, 10m | ||
|---|---|---|---|---|
| Turn Table Size | : | Φ5m in diameter,Weight Limit: 5,000kg | ||
| Size of Carrying-in Entrance | : | 3.0(W) × 3.0 (H) m | ||
| Test Frequency | : | 30MHz~40GHz | ||
| Power capacity | : | Single Phase / Three Phase : 45kVA | ||
| Size of Vertical Ground Reference Plane | : | 5.0 (W) × 2.0 (H) m (max.) | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||
2-2. Shield Room for Immunity
Shield Room for Immunity (nicknamed "Graz")

| Shield Room Size | : | 6.0 (W) ×10.0 (L) ×3.0 (H) m (Internal Usable Dimensions) |
||
|---|---|---|---|---|
| Test Standards | : | EN / IEC 61000-4-2 EN / IEC 61000-4-4 EN / IEC 61000-4-5 EN / IEC 61000-4-6 EN / IEC 61000-4-11 |
||
| Size of Carrying-in Entrance | : | 2.4 (W) × 2.0 (H) m | ||
| Power capacity | : | Single Phase / Three Phase : 8kVA and 12kVA (2systems) | ||
| Shield Capacity | : | 9KHz~40GHz | ||
| Power Outlet Frequency | : | 50Hz, 60Hz | ||
| Other Test Standards | : | EN / IEC 61000-4-8 (in Ambient Chamber) EN / IEC 61000-3-2 (in another chamber for harmonics) EN / IEC 61000-3-3 (in another chamber for flicker) |
||